AIA-360
SKU: AIA-360
AUTOMATED IMMUNOASSAY ANALYZER
The AIA-360 sample carousel holds up to 25 patient samples and 25 test cups at one time.
First result in ~ 20 minutes.
Bar-code sample ID ensures accurate patient identification without manual worklist entry.
ADDITIONAL INFORMATION
Sophisticated Diagnostics in a Compact Analyzer
Reliable Solution for Low Volume Testing
- Throughput of 36 Results per Hour
- Full Test Menu
- Easy to Use
- STAT Assay Results in ~ 20 Minutes
- Random Access
- Compact - 16”w x 16”d x 21”h / 61lbs
- Fits Multiple Laboratory Environments:
- Small hospitals
- Physician Office Laboratories
- Cardiac and Specialty Testing
- Reliable Back-up to Larger Tosoh Analyzers
REAGENT TECHNOLOGY
Tosoh’s AIA Reagent Test Cup Technology
- Unit Dose Test Cup reagent technology requires no on-board refrigeration, no pre-mixing and no pre-measuring.
- Saves time and cost by eliminating errors and waste.
- Complete test menu.
- Reagents have a one year shelf life from date of manufacture.
- 90-day calibration stability most assays.
SYSTEM ADVANTAGES
User Friendly Interface
- Icon driven touch screen is intuitive and is easy to navigate.
- Assay monitoring enables the user to check sample progress and assay performance.
- Sample ID’s can be manually programmed if non-barcoded specimens are utilized.
- The system can be interfaced to any LIS system.
- Up to 300 assay results can be saved on the AIA-360.
Advanced Sample Carousel
- The AIA-360 sample carousel holds up to 25 patient samples and 25 test cups at one time.
- The operator may load bar-coded primary tubes or sample cups directly on the system.
- Up to four assays per specimen can be loaded.
- Additional samples and tests can be added at any time without interrupting sample processing.
- Once samples and test cups are loaded, the operator presses START and walks away.
Fast and Accurate Results
- Prints patient results in real-time for fast and easy review.
- First result in ~ 20 minutes.
- Bar-code sample ID ensures accurate patient identification without manual worklist entry.
- Analyte is identified via an on-board camera.
Convenient Reagent Access
- The common reagents are easily accessible from the removable reagent tray.
- Reagent level sensors signal the user when reagents are running low or when the waste needs to be emptied.
Specifications
Method Fluorescence Enzyme Immunoassay Detection LED illuminant, non flow cell/TOP-TOP photometry met Throughput 36 tests per hour Reaction time Antigen antibody reaction: 10 minutes Sample loading Capacity 25 samples maximum Reagent loading Capacity 25 tests maximum Test for each sample 4 tests per sample Sampling Fixed Probe with Clot detection function Sample Vessel Primary Tube 13 x 75/100mm, 16 × 75/100mm 2 mL sample cup Barcode Code39, Code128, ITF, NW-7 and JAN Interface RS232C Size/Weight 16w x 16d x 21h • 61 lbs. Power source AC100 240VAC-50/60Hz 250VA Environment Temperature: 15-30o C, Relative Humidity 40-80% DOWNLOADABLE PDF