AUTOMATED IMMUNOASSAY ANALYZER

 

  • The AIA-360 sample carousel holds up to 25 patient samples and 25 test cups at one time.

  • First result in ~ 20 minutes.

  • Bar-code sample ID ensures accurate patient identification without manual worklist entry.

  • ADDITIONAL INFORMATION

    Sophisticated Diagnostics in a Compact Analyzer

     

    Reliable Solution for Low Volume Testing

    • Throughput of 36 Results per Hour
    • Full Test Menu
    • Easy to Use
    • STAT Assay Results in ~ 20 Minutes
    • Random Access
    • Compact - 16”w x 16”d x 21”h / 61lbs
    • Fits Multiple Laboratory Environments:
      - Small hospitals
      - Physician Office Laboratories
      - Cardiac and Specialty Testing
      - Reliable Back-up to Larger Tosoh Analyzers

     

    REAGENT TECHNOLOGY

    Tosoh’s AIA Reagent Test Cup Technology

    • Unit Dose Test Cup reagent technology requires no on-board refrigeration, no pre-mixing and no pre-measuring.
    • Saves time and cost by eliminating errors and waste.
    • Complete test menu.
    • Reagents have a one year shelf life from date of manufacture.
    • 90-day calibration stability most assays.

     

    SYSTEM ADVANTAGES

    User Friendly Interface

    • Icon driven touch screen is intuitive and is easy to navigate.
    • Assay monitoring enables the user to check sample progress and assay performance.
    • Sample ID’s can be manually programmed if non-barcoded specimens are utilized.
    • The system can be interfaced to any LIS system.
    • Up to 300 assay results can be saved on the AIA-360.

     

    Advanced Sample Carousel

    • The AIA-360 sample carousel holds up to 25 patient samples and 25 test cups at one time.
    • The operator may load bar-coded primary tubes or sample cups directly on the system.
    • Up to four assays per specimen can be loaded.
    • Additional samples and tests can be added at any time without interrupting sample processing.
    • Once samples and test cups are loaded, the operator presses START and walks away.

     

    Fast and Accurate Results

    • Prints patient results in real-time for fast and easy review.
    • First result in ~ 20 minutes.
    • Bar-code sample ID ensures accurate patient identification without manual worklist entry.
    • Analyte is identified via an on-board camera.

     

    Convenient Reagent Access

    • The common reagents are easily accessible from the removable reagent tray.
    • Reagent level sensors signal the user when reagents are running low or when the waste needs to be emptied.

     

    Specifications

    Method Fluorescence Enzyme Immunoassay
    Detection LED illuminant, non flow cell/TOP-TOP photometry met
    Throughput 36 tests per hour
    Reaction time Antigen antibody reaction: 10 minutes
    Sample loading Capacity 25 samples maximum
    Reagent loading Capacity 25 tests maximum
    Test for each sample 4 tests per sample
    Sampling Fixed Probe with Clot detection function
    Sample Vessel Primary Tube 13 x 75/100mm, 16 × 75/100mm 2 mL sample cup
    Barcode Code39, Code128, ITF, NW-7 and JAN
    Interface RS232C
    Size/Weight 16w x 16d x 21h • 61 lbs.
    Power source AC100 240VAC-50/60Hz 250VA
    Environment Temperature: 15-30o C, Relative Humidity 40-80%