AIA-900-19
FULLY AUTOMATED ENZYME IMMUNOASSAY ANALYZER
90 tests/hour throughput
First result in ~ 18 minutes
Random access / Continuous processing
90 day calibration for most assays
Simple touch screen operation
ADDITIONAL INFORMATION
Four Configurations Provide Expansion Capabilities
Features:
- 90 tests/hour throughput
- First result in ~ 18 minutes
- Random access / Continuous processing
- 90 day calibration for most assays
- Simple touch screen operation
- Bar-coded primary tube sampling
- Clot detection
- Automated pretreatment
- Automated dilution from 2 to 1000
Four Configurations for Different Sizes of Labs and Workloads
AIA-900 Benchtop
• 90 tests/hour throughput
• Load 10 racks on boardDimensions - W/D/H:
40” x 26.18” x 30”
1016 mm x 665 mm x 762 mmAIA-900 Loader Model
• 90 tests/hour throughput
• Load 10 racks on board
Dimensions - W/D/H:
35.04” x 26.18” x 49.09”
890 mm x 665 mm x 1247 mmAIA-900 with 9 Tray Sorter
• 90 tests/hour throughput
• Load 9 trays (20 cups/tray)
• Load 10 sample racks
• Load 100 patient samples
• Increased walkaway time with loading 180 test cupsDimensions - W/D/H:
50.79” x 26.18” x 49.09”
1290 mm x 665 mm x 1247 mmAIA-900 with 19 Tray Sorter
• 90 tests/hour throughput
• Load 19 trays (20 cups/tray)
• Maximize walkaway time with loading 380 test cups
• Load 10 sample racks • Load 100 patient samplesDimensions - W/D/H:
59.84” x 26.18” x 49.09”
1520 mm x 665 mm x 1247 mmUnit Dose Test Cup Reagent Technology
The AIA-PACK test cup format works with every Tosoh AIA Automated Immunoassay System. Reagents are interchangeable, so laboratories with more than one Tosoh system can use the same reagents. Transition between systems is seamless, ensuring consistent results and efficient, economical operation for the laboratory
It is very easy for a lab to add a 9 or 19 tray sorter to the instrument. The reagent’s performance does not change since the analysis section of the instrument remains the same.
AIA-900 Specifications
Principle of measurement Fluorescent enzyme immunoassay (FEIA) method Processing method Fully automated continuous random access Processing ability Max. 90 tests/hour (ST reagent) Specimen quantity 10 - 125 μL Specimen clogging detection Pressure detection method Measurement condition Reaction temperature: 37°C Reaction time Antigen-antibody reaction time: 10 minutes, 20 minutes, 40 minutes Specimen dilution function Dilution ratios between 2 and 1000 can be selected for each assay Detection method Fluorescent measurement (top-top method) Number of sample rack sets Max. 10 Number of samples and reagent cups Max. 100 Specimen containers 13 × 75 mm, 13 × 100 mm, 16 × 75 mm, 16 × 100 mm (outside diameter × length of test tube) Dedicated sample cups Specimen barcode Supports CODE39, CODE128, ITF, NW-7, JAN/EAN/UPC, industrial 2of5, and COOP2of5 Sample tip Dedicated tip Number of installed sample tips Max. 192 tips (96 tips/rack in 2 racks) Number of reagent sets Max. number of reagent vials: 12, Max. number of reagent bottles: 4 External output RS232C Power source/consumption 100 - 240 VAC, 50/60 Hz, 300 VA External dimensions AIA-900 Benchtop- W/D/H: 40” x 26.18” x 30”; 1016 mm x 665 mm x 762 mm
AIA-900 Loader Model - W/D/H: 35.04” x 26.18” x 49.09”; 890 mm x 665 mm x 1247 mm
AIA-900 with 9 Tray Sorter - W/D/H: 50.79” x 26.18” x 49.09”; 1290 mm x 665 mm x 1247 mm
AIA-900 with 19 Tray Sorter - W/D/H: 59.84” x 26.18” x 49.09”; 1520 mm x 665 mm x 1247 mm
Temperature 15 °C - 30 °C (degrees Celsius) Humidity 40 % - 80 % R.H. (non-condensing) EMC standard IEC61326-1: 2005, IEC61326-2-6: 2005 DOWNLOADABLE PDF