Atellica Hema 570/580
High throughput model with automation
High-throughput hematology with 120 samples/hour — Atellica Hema 570/580 combines optical platelet and reticulocyte analysis with 43 to 55 reportable parameters.
ADDITIONAL INFORMATION
TECHNICAL SPECIFICATIONS
Atellica HEMA 570 and 580 Analyzers
Parameters
CBC Results WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, MIC%,* MAC%,* PLT, MPV, PCT,* PDW,* NRBC (absolute and %) Differential Results (Absolute and %) LYM, MON, NEU, EOS, BAS, ALY,* LIC,* IMG,* IML,* IMM* Platelet Results (Optical)† PLTO Reticulocyte Results† RET (absolute and %), RETL%,* RETM%,* RETH%,* CRC%, MRV,* MFI,* IRF, RHCc, PIC* Body Fluid Results
Cerebrospinal, Pleural, Peritoneal, and Synovial Fluids BFWBC, BFRBC, absolute and % BFMN, BFPN Test Selectivity/Throughput
CBC 120 samples/hour DIFF (incl. NRBC) 120 samples/hour RET† 60 samples/hour DIR (incl. NRBC)† 60 samples/hour CBR† 60 samples/hour DIFF_LV 60 samples/hour RBC_PLTO† 60 samples/hour Sample Modes/Volumes
Automatic Rack Mode (Closed Tube) 110 μL STAT Mode (Closed/Open Tube) 110 μL Weight/Dimensions
Atellica® HEMA 570 Analyzer Weight: 94 kg (207 lb) 73 cm (h) x 87 cm (w) x 67 cm (d) 28.8 in. (h) x 34.3 in. (w) x 26.4 in. (d) Atellica® HEMA 580 Analyzer Weight: 99 kg (218 lb) 73 cm (h) x 87 cm (w) x 67 cm (d) 28.8 in. (h) x 34.3 in. (w) x 26.4 in. (d) Atellica HEMA 570 and 580 Analyzer Specifications
User Interface Specifications
ComputerWINDOWS Embedded Standard 10 operating system, 250 GB hard drive, 2 GB memory, INTEL Celeron J1900 QuadCore 2 GHz processor, 12.1-inch integrated color LCD touch screen, full-sized keyboard, Ethernet and USB connections
Other Specifications
Automated daily cleaning (startup/after 100 analyses/shutdown); recommended concentrated cleaning weekly or after every 1000 analyses
Performance Specifications
Linear RangesWBC 0.1–300 x 103/mm3 RBC 0.3–8 x 106/mm3 PLT (HGB > 2) 10–2500 x 103/mm3 (HGB < 2) 10–5000 x 103/mm3 HGB 0.8–24 g/dL RET% 0.3–35 (%) Data Management Database 100,000-patient storage capacity, including graphics Review and Edit Capability Atellica® Data Manager enables user-defined windows, userdefined reports, user-defined ranges based on age and sex for normal range, panic, rerun, and delta check criteria Extensive Quality Control (QC) Management Z-score, Levey-Jennings graphs, Westgard rules, patient moving average (enabled by Atellica Data Manager), QC file management Online Documentation Operator's manual, remote diagnostics Physical Specifications Electrical Power Requirements Voltage: 100–240 VAC (±10%) Frequency: 50–60 Hz Temperature Requirements 15–30°C. If stored at a temperature lower than 10°C, analyzer should stand for 1 hour at normal room temperature before use. Relative Humidity 85% maximum, without condensation. Heat Generation 715Kj/h (675 BTU/h) Waste Disposal Direct plumbing or external waste container Audible Noise <60 dB at 1 meter Sample Loading Specifications Automatic Rack Loading 120-tube capacity (12 racks with 10-tube capacity) Compatible Tube Types CAPIJECT, CARRIER, GK, INSEPACK, KABEVETTE, MICROTAINER, MICROVETTE, MINICOLLECT, MONOJECT, MONOVETTE, MULTIVETTE, NEO, VACUETTE, VACUTAINER Barcode Reader Up to 16 characters Automatic Discrimination of Label Codes Interleaved 2-of-5 with or without check digit, Code 39 with or without check digit, Codabar without check digit, Code 128 DOWNLOADABLE PDF