top of page

BC-6000

SKU: BC-6000

Auto Hematology Analyzer

 

High Performance for ALL

 

BC-6000 provides a dedicated ag called “infected RBC?”, and “InR*(#,‰)”parameters to represent the number and ratio of the infected red blood cells in the sample respectively.

  • ADDITIONAL INFORMATION

    Auto Hematology Analyzer

     

    Principles

     

    SF Cube* method to count WBC, 5-Part di and NRBC DC impedance method for RBC and PLT Cyanide free reagent for hemoglobin test *S: Scatter; F: Fluorescence; Cube: 3D analysis

     

    Parameters

     

    29 Reportable parameters (whole blood): WBC, Lym%, Mon%, Neu%, Bas%, Eos%, IMG%, Lym#, Mon#, Neu#, Eos#, Bas#, IMG#; RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, NRBC#, NRBC%; PLT, MPV, PDW, PCT, P-LCR, P-LCC 20 Research parameters (whole blood): HFC#, HFC%, WBC-D, TNC-D, IME%, IME#, H-NR%, L-NR%, NLR, PLR, WBC-N, TNC-N, InR#, InR‰, Micro#, Micro%, Macro#, Macro%, PDW-SD, PLT-I 7 Reportable parameters (body uid): WBC-BF, TC-BF#, MN#, MN%, PMN#, PMN%, RBC-BF 11 Research parameters (body uid): Eos-BF#, Eos-BF%, Neu-BF#, Neu-BF%, HF-BF#, HF-BF%, RBC-BF, LY-BF, LY-BF%, MO-BF#, MO-BF%

     

    2 Histograms for RBC and PLT

    2 Three-dimension scatter grams: DIFF, WNB

    2 Two-dimension scatter grams: DIFF, WNB

     

    Mode

     

    CBC, CBC+DIFF

     

    Data storage capacity

     

    Up to 10,0000 results including numeric and graphical information

     

    Operating environment

     

    Temperature: 15℃~32℃

    Humidity:  30%~85%

     

    Performance

    Parameter Linearity Range Precision Carryover
    WBC 0-500×109 /L ≤2.5% (≥4×109 /L) ≤1.0%
    RBC 0-8.60×1012/L ≤1.5% (≥3.5×1012/L) ≤1.0%
    HGB 0-260g/L ≤1.0% (110-180g/L) ≤1.0%
    HCT 0-75% ≤1.5% (30%-50%) ≤1.0%
    PLT 0-5000×109 /L ≤4.0% (≥100×109 /L) ≤1.0%

     

    Sample volume

    Whole blood (Autoloader, Closed Tube)    80uL
    Capillary blood (Closed Tube) 35uL
    Predilute (Closed Tube) 20uL
    Body fluid (Closed Tube) 85uL

     

    Throughput

    Up to 110 samples per hour (CBC+DIFF)

    Up to 40 samples per hour (Body fluid)

     

    Loading capacity

    Up to 50 sample tubes

     

    At Mindray, we seek to understand the needs of every customer, and deliver tailor-made solutions. Before designing any product, we listen to the Voice Of Customers and bear in mind the challenges they face. In today’s laboratories, lab managers are looking for an analyzer with greater clinical values, such as higher flagging efficiency to reduce the ratio of microscopic examination, NRBC/body fluid results generated in a small-footprint system, among others, all within limited budget.

     

    Mindray BC-6000 fulfills all these requirements and exceeds your expectations with so much more in terms of Value, Operation and Cost.

     

    DIFF Channel

     

    In DIFF scattergram, BC-6000 not only gives WBC 5-part differential results (with immature granulocyte), but also brings research parameters such as HFC (Blast & Atypical Lymphocyte), InR (information about malaria) and flags for Band, NRBC, PLT clump and Atypical Lymphocyte.

     

    HFC*(#, %) parameters represent high population of fluorescent cell, such as Blasts and Atypical Lymphocytes.

     

    IMG(#, %) parameters provide information about immature granulocytes, including Promyelocytes, Myelocytes, Metamyelocytes, Immature Eosinophils and Immature Basophils.

     

    Malaria screening

     

    BC-6000 provides a dedicated flag called “infected RBC?”, and “InR*(#,‰)”parameters to represent the number and ratio of the infected red blood cells in the sample respectively. BC-6000 users can obtain information about the possible presence of plasmodium parasite, the causative agent of malaria infection. With the rising number of red blood cells with malaria parasites, the number of dots in the “InR” area increases proportionately. This creates the possibility to not only screen but also judge the severity of malaria infection.

     

    Interference prevention

     

    In DIFF scattergram, WBCs are dyed, but not lipid particles, by fluorescence, which prevents interference and ensures more accurate WBC results. With information obtained through the 3D analysis, PLT clumps are well separated from each cluster of WBCs.

     

    WNB Channel

     

    In WNB scattergram, BC-6000 provides NRBC, Basophils and WBC-N* results. It means that the actual number of NRBCs can be measured in routine CBC, if they are present in the sample. Basophils are counted in this counting channel with NRBC results.

    Basophil and NRBC results are generated on BC-6000 without extra reagent or cost.

     

    NRBC results in every CBC

    • Automatic correction WBC counting, make sure neonatal counting correctly
    • Diagnosis for hemolytic anemia
    • Monitoring of hematopoietic diseases
    • Reduce the ratio of review

     

    Body fluid

    • Peritoneal fluid
    • Pleural fluid
    • Cerebrospinal fluid (CSF)
    • Synovial fluid

     

    Besides blood specimen, BC-6000 also has body fluid test function without requiring dedicated reagent. The various types of body fluids include Peritoneal fluid, Pleural fluid, Cerebrospinal fluid (CSF) and Synovial fluid.

     

    Applicable to variety of tubes

     

    To cater to customer’s diversified needs, different types of blood collection tubes can be used on BC-6000 , including regular whole blood vacuum tube, capillary blood microtainer tube and Sarstedt tube.

     

    More Intuitive labXpert software

     

    LabXpert is a standard configuration of BC-6000 for professional data analysis. The labXpert software optimizes functions to simplify your workflow for data analysis including improving re-exam efficiency, auto-validation for normal samples; it also provides more intuitive interface for you to review and validate pathological samples.

     

    Automatic Rerun & Reflex

     

    Should the sample results trigger the criteria, the autoloader of BC-6000 can return the sample racks for an automatic rerun or reflex check.

     

    Easy maintenance

     

    The only maintenance for end user is daily shut down by probe cleanser or probe cleanser cleaning once per day (if not shut down). The “auto-protect” program reminds operators when maintenance is needed (if not shut down).

     

    Low sample volume

     

    BC-6000 requires less sample volume as well as reagent consumption. For a CBC+DIFF test with NRBC result, BC-6000 only requires 80μL of whole blood and 35 μL of capillary blood.

     

    Less testing time

     

    BC-6000 can load up to 50 samples at a time and offers a throughput of up to 110 tests per hour.

  • DOWNLOADABLE PDF

Order products like this and more call 305-593-2137 or fill out the form below.

Contact us

bottom of page