BC-6200
Auto Hematology Analyzer
High Performance for ALL
In DIFF scattergram, BC-6200 not only gives WBC 5-part dierential results (with immature granulocyte), but also brings research parameters such as HFC (Blast & Atypical Lymphocyte), InR (information about malaria)
ADDITIONAL INFORMATION
High Performance for ALL
Principles
SF Cube* method to count WBC, 5-part di, NRBC, RET and PLT-O DC impedance method for RBC and PLT Cyanide free reagent for hemoglobin test *S: Scatter; F: Fluorescence; Cube: 3D analysis
Parameters
37 Reportable parameters (whole blood): WBC, Lym%, Mon%, Neu%, Bas%, Eos%, IMG%, Lym#, Mon#, Neu#, Eos#, Bas#, IMG#; RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, NRBC#, NRBC%; PLT, MPV, PDW, PCT, P-LCR, P-LCC, RET%, RET#, RHE, IRF, LFR, MFR, HFR, IPF 29 Research parameters (whole blood): HFC#, HFC%, RBC-O, PLT-O, PLT-I, WBC-O, WBC-D, TNC-D, IME%, IME#, H-NR%, L-NR%, NLR, PLR, WBC-N, TNC-N, InR#, InR‰, Micro#, Micro%, Macro#, Macro%, RPI, H-IPF, IPF#, MRV, FRC#, FRC%, PDW-SD 7 Reportable parameters (body fluid): WBC-BF, TC-BF#, MN#, MN%, PMN#, PMN%, RBC-BF 11 Research parameters (body fluid): Eos-BF#, Eos-BF%, Neu-BF#, Neu-BF%, HF-BF#, HF-BF%, RBC-BF, LY-BF, LY-BF%, MO-BF#, MO-BF%
2 Histograms for RBC and PLT
3 Three-dimension scatter grams: DIFF, WNB, RET
5 Two-dimension scatter grams: DIFF, WNB, RET, RET-EXT, PLT-O
Mode
CBC, CBC+DIFF, CBC+DIFF+RET, CBC+RET, RET
Data storage capacity
Up to 10,0000 results including numeric and graphical information
Operating environment
Temperature: 15℃~32℃
Humidity: 30%~85%
Performance
Parameter Linearity Range Precision Carryover WBC 0-500×109 /L ≤2.5% (≥4×109 /L) ≤1.0% RBC 0-8.60×1012/L ≤1.5% (≥3.5×1012/L) ≤1.0% HGB 0-260g/L ≤1.0% (110-180g/L) ≤1.0% HCT 0-75% ≤1.5% (30%-50%) ≤1.0% PLT 0-5000×109 /L ≤4.0% (≥100×109 /L) ≤1.0% RET# 0-0.8×1012/L ≤15% (RBC≥3×1012/L; 1%≤RET%≤4%) / At Mindray, we seek to understand the needs of every customer, and deliver tailor-made solutions. Before designing any product, we listen to the Voice Of Customers and bear in mind the challenges they face. In today’s laboratories, lab managers are looking for an analyzer with greater clinical values, such as higher flagging efficiency to reduce the ratio of microscopic examination, NRBC/RET/body fluid results generated in a small-footprint system, among others, all within limited budget.
Mindray BC-6200 fulfills all these requirements and exceeds your expectations with so much more in terms of Value, Operation and Cost.
DIFF Channel
In DIFF scattergram, BC-6200 not only gives WBC 5-part differential results (with immature granulocyte), but also brings research parameters such as HFC (Blast & Atypical Lymphocyte), InR (information about malaria) and flags for Band, NRBC, PLT clump and Atypical Lymphocyte.
HFC*(#, %) parameters represent high population of fluorescent cell, such as Blasts and Atypical Lymphocytes.
IMG(#, %) parameters provide information about immature granulocytes, including Promyelocytes, Myelocytes, Metamyelocytes, Immature Eosinophils and Immature Basophils
Malaria screening
BC-6200 provides a dedicated flag called “infected RBC?”, and “InR*(#,‰)”parameters to represent the number and ratio of the infected red blood cells in the sample respectively. BC-6200 users can obtain information about the possible presence of plasmodium parasite, the causative agent of malaria infection. With the rising number of red blood cells with malaria parasites, the number of dots in the “InR” area increases proportionately. This creates the possibility to not only screen but also judge the severity of malaria infection.
Interference prevention
In DIFF scattergram, WBCs are dyed, but not lipid particles, by fluorescence, which prevents interference and ensures more accurate WBC results. With information obtained through the 3D analysis, PLT clumps are well separated from each cluster of WBCs.
WNB Channel
In WNB scattergram, BC-6200 provides NRBC, Basophils and WBC-N* results. It means that the actual number of NRBCs can be measured in routine CBC, if they are present in the sample. Basophils are counted in this counting channel with NRBC results. Basophil and NRBC results are generated on BC-6200 without extra reagent or cost.
RET Channel
With the SF Cube cell analysis technology, Reticulocytes are differentiated from the other red cells by their reaction with fluorescent stain. Besides the traditional parameters such as RET# and RET%, BC-6200 provides data concerning immature reticulocytes (IRF), which can assist in early diagnosis of anemia and monitoring the bone marrow response to therapy.
Bodyfluid
Besides blood specimen, BC-6200 also has body fluid test function without requiring dedicated reagent. The various types of body fluids include Peritoneal fluid, Pleural fluid, Cerebrospinal fluid (CSF) and Synovial fluid.
- Peritoneal fluid
- Pleural fluid
- Cerebrospinal fluid (CSF)
- Synovial fluid
Applicable to variety of tubes
To cater to customer’s diversified needs, different types of blood collection tubes can be used on BC-6200 , including regular whole blood vacuum tube, capillary blood microtainer tube and Sarstedt tube.
More Intuitive labXpert software
LabXpert is a standard configuration of BC-6200 for professional data analysis. The labXpert software optimizes functions to simplify your workflow for data analysis including improving re-exam efficiency, auto-validation for normal samples; it also provides more intuitive interface for you to review and validate pathological samples.
Automatic Rerun & Reflex
Should the sample results trigger the criteria, the autoloader of BC-6200 can return the sample racks for an automatic rerun or reflex check.
Easy maintenance
The only maintenance for end user is daily shut down by probe cleanser or probe cleanser cleaning once per day (if not shut down). The “auto-protect” program reminds operators when maintenance is needed (if not shut down).
Low sample volume
BC-6200 requires less sample volume as well as reagent consumption. For a CBC+DIFF+RET test with NRBC result, BC-6200 only requires 80μL of whole blood and 35 μL of capillary blood.
Less testing time
BC-6200 can load up to 50 samples at a time and offers a throughput of up to 110 tests per hour.