Mindray BS-360E

SKU: BS-360E

Complete calibration hierarchy and traceability chain are based on ISO standard (EN/ISO17511) from reference system to routine measurement system.

  • TECHNICAL SPECIFICATIONS

    System Function
    Automatic, Discrete, Random Access, Bench-top
    STAT Sample Priority
    Available
    Throughput
    Up to 360 photometric tests per hour; up to 540 tests/hour with ISE
    Measuring Principles
    Absorbance Photometry, Turbidimetry, Ion Selective Electrode (ISE) Technology
    Methodology End-point, Fixed-time, Kinetic, Optional ISE, Single/Double Reagent Chemistries, Monochromatic/Bi-chromatic
    Reagent System
    Original system pack reagent ready to use
    System Type

    Closed system (standard) and open system (optional)

     

     

    Reagent/Sample tray 50 to 100 positions for reagents and 50 to 100 positions for samples in 24-hour refrigerated compartment (2~12℃)
    Reagent volume R1: 100~200μL, step by 0.5μL R2: 10~200μL, step by 0.5μL
    Sample volumne 2~35μL, step by 0.1μL
    Reagent/Sample probe Liquid level detection, vertical collision protection, inventory checking, reagent pre-warming, optional clog detection
    Probe cleaning

    Automatic washing for interior and exterior

    Carry over < 0.05%

    Automatic sample dilution Pre-dilution and post-dilution
    Mixing Unit Independent mixing bar

     

    Reaction tray 80 reusable cuvettes
    Reaction volume 100~360μL
    Reaction temperature 37℃± 0.1℃
    Cuvette Washing Washing station with pre-warmed detergent and de-ionized water

     

    ISE Module  (optional)
    Measuring K+, Na+, Cl

     

    Light Source Halogen-tungsten lamp
    Wavelength 12 wavelengths, 340nm, 380nm, 412nm, 450nm, 505nm, 546nm, 570nm, 605nm, 660nm, 700nm, 740nm, 800nm
    Absorption range 0~3.5Abs, resolution 0.0001Abs
    Stray Light 4.9Abs

     

    Calibration modes K factor, Linear (two points and multipoints), Logit-Log 4P, Logit-Log 5P, Spline, Exponential, Polynomial, Parabola, Logit-Log3P, Broken line One key calibrator import function
    Control Rules: Westgard multi-rule, Levey-Jennings, Cumulative sum check, Twin plot

     

    Operation system Windows 10
    Interface RS-232

     

    Power Supply 200~240V, 50/60Hz, ≤1300VA or 100~130V, 60Hz, ≤1300VA
    Dimension 860 mm (length) × 660 mm (depth) × 550 mm (height)
    Weight 115 kg
    Water Consumption ≤6.5 L/H

     

     

  • ADDITIONAL INFORMATION

    A Whole New Generation

    • with throughput up to 360 photometric T/H
    • Large and flexible capacity Up to 100 sample positions Up to 100 reagent positions (50 fixed + 50 interchangeable)
    • Considerate design More space to load samples
    • HbA1c smart-sampling function Automatic preparation of hemolysateGratings photometer 100μL minimum reaction volume

     

    BS-360E Chemistry Analyzer

    • Waterfall probe cleaning
    • Intelligent probe with optional clog detection
    • Throughput of up to 360T/H
    • Independent mixing bar
    • Optimized washing station
    • Built-in barcode reader
    • Optional ISE module easy to access
    • Intuitive software with more functionalities

     

    Complete traceability process

    Complete calibration hierarchy and traceability chain are based on ISO standard (EN/ISO17511) from reference system to routine measurement system.

     

    External quality assurance for reference measurement

    Mindray participates in RELA (External quality control for reference laboratory).

     

    EQA for Mindray Reference laboratory——RELA

    Mindray reference laboratory has passed RELA for 6 consecutive years.