Mindray BS-360E
SKU: BS-360E
Complete calibration hierarchy and traceability chain are based on ISO standard (EN/ISO17511) from reference system to routine measurement system.
TECHNICAL SPECIFICATIONS
System Function Automatic, Discrete, Random Access, Bench-top STAT Sample Priority Available Throughput Up to 360 photometric tests per hour; up to 540 tests/hour with ISE Measuring Principles Absorbance Photometry, Turbidimetry, Ion Selective Electrode (ISE) Technology Methodology End-point, Fixed-time, Kinetic, Optional ISE, Single/Double Reagent Chemistries, Monochromatic/Bi-chromatic Reagent System
Original system pack reagent ready to useSystem Type Closed system (standard) and open system (optional)
Reagent/Sample tray 50 to 100 positions for reagents and 50 to 100 positions for samples in 24-hour refrigerated compartment (2~12℃) Reagent volume R1: 100~200μL, step by 0.5μL R2: 10~200μL, step by 0.5μL Sample volumne 2~35μL, step by 0.1μL Reagent/Sample probe Liquid level detection, vertical collision protection, inventory checking, reagent pre-warming, optional clog detection Probe cleaning Automatic washing for interior and exterior
Carry over < 0.05%
Automatic sample dilution Pre-dilution and post-dilution Mixing Unit Independent mixing bar Reaction tray 80 reusable cuvettes Reaction volume 100~360μL Reaction temperature 37℃± 0.1℃ Cuvette Washing Washing station with pre-warmed detergent and de-ionized water ISE Module (optional) Measuring K+, Na+, Cl Light Source Halogen-tungsten lamp Wavelength 12 wavelengths, 340nm, 380nm, 412nm, 450nm, 505nm, 546nm, 570nm, 605nm, 660nm, 700nm, 740nm, 800nm Absorption range 0~3.5Abs, resolution 0.0001Abs Stray Light 4.9Abs Calibration modes K factor, Linear (two points and multipoints), Logit-Log 4P, Logit-Log 5P, Spline, Exponential, Polynomial, Parabola, Logit-Log3P, Broken line One key calibrator import function Control Rules: Westgard multi-rule, Levey-Jennings, Cumulative sum check, Twin plot Operation system Windows 10 Interface RS-232 Power Supply 200~240V, 50/60Hz, ≤1300VA or 100~130V, 60Hz, ≤1300VA Dimension 860 mm (length) × 660 mm (depth) × 550 mm (height) Weight 115 kg Water Consumption ≤6.5 L/H ADDITIONAL INFORMATION
A Whole New Generation
- with throughput up to 360 photometric T/H
- Large and flexible capacity Up to 100 sample positions Up to 100 reagent positions (50 fixed + 50 interchangeable)
- Considerate design More space to load samples
- HbA1c smart-sampling function Automatic preparation of hemolysateGratings photometer 100μL minimum reaction volume
BS-360E Chemistry Analyzer
- Waterfall probe cleaning
- Intelligent probe with optional clog detection
- Throughput of up to 360T/H
- Independent mixing bar
- Optimized washing station
- Built-in barcode reader
- Optional ISE module easy to access
- Intuitive software with more functionalities
Complete traceability process
Complete calibration hierarchy and traceability chain are based on ISO standard (EN/ISO17511) from reference system to routine measurement system.
External quality assurance for reference measurement
Mindray participates in RELA (External quality control for reference laboratory).
EQA for Mindray Reference laboratory——RELA
Mindray reference laboratory has passed RELA for 6 consecutive years.