Medica EasyBloodGas
EasyBloodGas focuses on the laboratory’s need to deliver sample results economically. Unique electrode design, combined with precise control of calibrator volumes, ensure economical operation and a low cost per sample.
ADDITIONAL INFORMATION
With EasyBloodGas, Medica has redefined blood gas analyzer design
The sophistication of traditional blood gas analyzers has been packaged in a new compact format with a small footprint to save space. Gas tanks are eliminated. Gas and liquids have been mixed (tonometered) to create a convenient Reagent Module containing liquid calibrants. All components are combined into three simple modules, easily accessible by the user. Routine maintenance is limited to the replacement of electrodes and a single pump tube.
Medica’s EasyBloodGas analyzer measures pH, PCO2 and PO2 and calculates eleven additional parameters. Patient parameters, including FIO2 and Hb, can be entered using the digital keypad and integrated into patient results. Measured and calculated results are displayed and printed. Simple menus guide the user through analyzer operation. The modular design makes maintenance easy.
EasyBloodGas focuses on the laboratory’s need to deliver sample results economically. Unique electrode design, combined with precise control of calibrator volumes, ensure economical operation and a low cost per sample.
. . . Easy to use
Blood gas analyzer operation has never been simpler
The Universal Sampler adapts to both syringe and capillary samples. The sample probe’s self-wiping feature provides convenience, sample integrity and user safety.
Compact reagent module for convenience, economy and safety
Bulky gas tanks are replaced with liquid, tonometered calibrants, packaged in a convenient Reagent Module which also collects waste, protecting the user from biological hazards. The Reagent Module’s solid-state memory enables EasyBloodGas to track date code and reagent usage. Operation without interruption is assured.
Disposable, maintenance-free electrodes
Advanced membrane technology and novel packaging bring unprecedented convenience to electrode replacement. Medica’s integral membrane design means that membranes never need to be changed by the user, saving time and simplifying maintenance.
HOME MENU
- Analyze Sample
- Analyze QC
- Calibrate
- Daily Cleaner
- Second Menu
SETUP MENU
- Security Code
- User Options
- Configuration
- Reference Limits
- Patient Information
- Delete Data
DIAGNOSTICS
- Test Components
- Test Fluidics
- Sensor Status
- Prime Fluids
Simple menu-prompted operation with a touch of the keypad
EasyBloodGas can be programmed to conform with established lab protocols. The software allows selection of desired options, including Reference Limits, Quality Control Limits, Operator ID, and Patient Data.. . . Easy to maintain
EasyBloodGas can be maintained by anyone, anytime, anywhere
Innovative design simplifies maintenance, addressing the needs of the remote laboratory with limited access to technical service personnel. All service calls can be performed by fax or telephone, eliminating the need for on-site service. Diagnostic software displays component status, assuring quick troubleshooting. Modularity makes assembly and disassembly quick and easy.
Removal of the three plug-in modules—Reagent Module, Sensor Module and Valve Module—is accomplished without tools.
. . . Easy data management
Comprehensive quality control and data management
The EasyBloodGas quality control program calculates and stores complete statistics for the last 30 quality control results at each of three levels. A printed Levey-Jennings chart visually identifies trends. The data management program compares all patient results with ranges stored in memory and flags out-of-range results. Results are stored in memory for up to 64 patients.TECHNICAL SPECIFICATIONS
CLIA Classification: Moderate complexity Sample Type: Whole blood Sample Size: 100 µL Syringe 75 µL Capillary Measured Parameters pH 6.900 – 7.900 pH units PCO2 8.0 – 150.0 mmHg PO2 10 – 700 mmHg Calculated Parameters pH (T) (pH temperature corrected) PCO2 (T) (PCO2 temperature corrected) PO2 (T) (PO2 temperature corrected) TCO2 (Total Carbon Dioxide) 0 – 50 mmol/L HCO3 - (Bicarbonate) 0 – 50 mmol/L BEb (Base Excess in blood) -25.0 – 25.0 mmol/L BEecf (Base Excess in extra cellular fluid) -25.0 – 25.0 mmol/L SBC (Standard Bicarbonate) 0 – 50 mmol/L %SO2C (Oxygen Saturation calculated at normal P50 40.0 – 100.0% A-aDO2 (Alveolar arterial oxygen gradient) 0 – 700 mmHg RI (Respiratory Index) 0.0 – 70.0 Input Parameters Patient Temperature 5 – 45°C Hemoglobin 30 – 30.0 g/dL FIO2 10 – 100% Patient ID 14 digits Sample Temperature Control: 37°C +– 0.2°C Ambient Conditions: 5 – 30°C (59 – 86°F), 500 – 800 mmHg (max 15 PSI) 5 – 85% relative humidity, non-condensing
atmospheric air environment (21% PO2)
Analysis Time: 125 seconds Data Storage: 64 Patient results with Operator ID, Patient ID, Date and Time QC – up to 30 results for each Level (1, 2, 3 Calibration: Automatic or On-Demand Input/Output: Numeric keypad, graphic display, 27 column thermal printer, barcode reader port, RS-232 computer interface port Power: 100/115 ~ VAC, 50 – 60 Hz, 0.8 A or 220 ~ VAC, 50 – 60 Hz, 0.4A Size & Weight: 14.5" W x 12.5" H x 7" D (37 cm W x 32 cm H x 18 cm D) 16 lbs. (7.3 kg) with reagent module DOWNLOADABLE PDF