Mindray AF-300/600
The AF-300 expert system offers an outstanding tool for clinical microbiology laboratories to learn about the epidemiology, resistance mechanism and therapy-related information of microorganisms and antimicrobials based on multiple international clinical practice guidelines, laboratory standard guidelines and expert panels.
TECHNICAL SPECIFICATIONS
AF-300 AF-600 Capacity options 32 64 Height 700mm 700mm Width 500mm 500mm Depth 710mm 710mm Clearance (Right) 240mm 240mm Clearance (front) 298mm 298mm Weight 60±2kg 64±2kg Power requirement 110~220 V/A; 50~60Hz 10 amp circuit 110~220 V/A; 50~60Hz 10 amp circuit ADDITIONAL INFORMATION
Fighting Against AMR
- Antimicrobial resistance (AMR) is one of top 10 global public health threats facing humanity.
- A study concluded in 2019 over 1.2 million deaths could be directly attributed to AMR.
- And this number will go up to 10 million in 2050 and exceed that of deaths from cancer.
ACCURAYCY : YOU CARE, WE DO
The test hole structure is uniquely designed to be cone-shaped to facilitate bacterial growth and enrichment.
AF-300/600 incorporates a five-wavelength detection system, which accurately matches the characteristics of different biochemical color reactions to provide more detailed results and make the interpretation more accurate.
Each of the cells in the testing panel is detected and analyzed by an intelligent dynamic algorithm every 20 min. This ensures higher accuracy and a short detection time, reducing the report time to as low as 4 to 5 hours
To help control the spread of AMR bacteria within medical institutions and communities in the shortest time possible, Mindray AF-300/600 adopts direct minimum inhibited concentrations (MICs) for detecting emerging resistant pathogens with a smart streamlined workflow, providing timely and accurate results
Comprehensive ID/AST panels: Discover more possibilities
- The system provides panels with various combinations, i.e., Sensitivity-only Panel and Identification & Sensitivity Panel.
- The primary panel can identify over 500 bacterium species with high sensitivity, including Enterobacteriaceae, Non-fermentation bacteria, Staphylococci, Enterococci, Streptococci, Neisseria, Haemophilus, Yeast-like fungi, Corynebacterium*, Vibrio*, Bacilli*, and Anaerobes*. (* on development)
- 96 wells are designed to combo ID/AST panel
- The primary panel can identify various emerging resistance mechanisms that may be present in samples, including MRSA, BORSA, MRCoNS, VISA, hVISA, VRSA, VRE, HLGR, CRE, CRAB, CRPAE, MLSb, PRSP, PISP, and BLNAR.
- Estimation of susceptibility based on serial double microbroth dilution of MICs in line with CLSI and EUCAST guidelines, without skipping the dilution of antibiotics.
Comprehensive ID/AST panels:
Uniquely designed for fastidious and yeast-like fungi
Antibiotics TDR NH-96 TDR NH-AST Penicillin 0.03-4 Ampicillin 0.12-2 0.06-4 Chloramphenicol 2-16 1/0.5-4/ 1-8 Ampicillin-sulbactam 1/0.5-4/2 1/0.5-4/2 Cefuroxime 2-8 2-16 Ceftazidime 1-2 Cefixime 0.5-2 0.5-2 Amoxicillin-clavulanic acid 2/1-8/4 2/1-8/4 Piperacillin - tazobactam 0.5/4-2/4 Meropenem 0.25-8 0.12-16 Ceftriaxone 0.12-2 0.12-2 Cefepime 0.25-2 0.25-2 Aztreonam 1-2 2-4 Lomefloxacin 1-2 1-2 Azithromycin 0.25-4 0.25-4 Erythromycin 1-2 Clindamycin 0.5-2 Tetracycline 1-4 1-4 Levofloxacin 0.03-4 0.03-4 Rifampin 0.5-2 0.12-4 Co-trimoxazole 0.12/2.4-2/38 0.12/2.4-4/76 TDR NH-96/AST
- 21 antibiotics included for β-lactamase testing
- A full range of concentrations for testing, including S/I/R breakpoints from CLSI and Eucast (2022)
- Modified M-H Broth without defibrillated blood
- Designed for Haemophilus, Neisseria, and Moraxella catarrhalis
Antifungal Drugs Yeast-96 Yeast-AST Flucytosine 0.5-64 0.12-128 Amphotericin B 0.25-4 0.008-4 Ketoconazole 0.5-32 Itraconazole
0.06-2 0.008-4 Fluconazole 0.002-64 0.12-128 Caspofungin 0.002-8 0.008-8 Micafungin 0.002-8 0.008-8 Voriconazole 0.06-2 0.008-8 Terbinafine 0.008-8
TDR YEAST-96/AST
- 8 to 9 antifungal drugs included in each panel, including caspofungin and micafungin
- Designed for yeast-like fungi
- A full range of concentrations for testing, including S/I/R breakpoints from CLSI and EUCAST (2022)
- Serial double dilution for each tested antifungal facilitates clinical and epidemiology research
A smart workflow enhances efficiency for laboratories
- Inoculation is performed by an automated dosing system to ensure accuracy and safety.
- Panel ID barcodes are scanned in batch with the in-built barcode scanner to ensure efficient panel loading.
- Panels that are ready for unload are automatically collected for batch unload.
A smart workflow enhances efficiency for labs
EXPERT SYSTEM ~ Better interpretation of ID and AST results
The AF-300 expert system offers an outstanding tool for clinical microbiology laboratories to learn about the epidemiology, resistance mechanism and therapy-related information of microorganisms and antimicrobials based on multiple international clinical practice guidelines, laboratory standard guidelines and expert panels.
- ID encyclopedia provides morphology, culture and epidemiology information to medically important bacteria and fungi
- User-definable expert rules can be easily figured as enabled v/s manual interpretation v/s automated interpretation
- Provides detailed information for result interpretation, such as like intrinsic resistance, contradictory resistance and rare resistance
- Pools together treatment suggestions from multiple international clinical practice guidelines for certain MDR bacteria and management reports
WHONET CONNECTION ~ Seamless convergence
One-click export and submission of WHONET analysis, requiring no other software for data format conversion
RESULT STATISTICS ~ Real-time monitoring
Generates antibiograms, tendency of AMR and other results upon request