Mindray BS-240
Complete calibration hierarchy and traceability chain are based on ISO standard (EN/ISO17511) from reference system to routine measurement system.
ADDITIONAL INFORMATION
Features:
- Flexible loading: Up to 80 sample positions, Up to 80 reagent positions. (40 xed + 40 interchangeable)
- Smart-Sampling Technology: Automatic hemolysate preparation for HbA1c test
- 100μl minimum reaction volume
- Upgraded auto-washing system ensures low carryover and low water consumption.
Compact Size with Robust Functions
- Independent mixing bar
- Built-in barcode reader
- Intelligent software with user-friendly interface
- Step-by-step maintenance guide
- Waterfall probe cleaning
Complete traceability process
Mindray testing system has passed CAP for 6 consecutive years. Complete calibration hierarchy and traceability chain are based on ISO standard (EN/ISO17511) from reference system to routine measurement system.
External quality assurance for reference measurement
Mindray participates in RELA (External quality control for reference laboratory) and CAP (College of American Pathologists external quality control)
TECHNICAL SPECIFICATIONS
System Function Automatic, Discrete, Random Access, Bench-top STAT sample priority Available Throughput Up to 200 tests/hour, up to 400 tests/hour with ISE Measuring Principles Absorbance photometry, Turbidimetry, Ion Selective Electrode technology Methodology End-point, Fixed-time, Kinetic, optional ISE, Single/Dual/ reagent chemistries, monochromatic / bi-chromatic Reagent System Original system pack reagent ready to use System Type Close system and open system is optional Reagent/Sample Handling
Reagent/Sample tray 80 positions for reagents and 40 positions for samples in 24-hour refrigerated compartment (2~12℃) Reagent volume 10~250μl, step by 0.5μl Sample volume 2~45μl, step by 0.1μl Reagent/Sample probe Liquid level detection, vertical collision protection and inventory checking, reagent pre-warming Probe cleaning Automatic washing for interior and exterior Carry over < 0.05% Automatic sample dilution Pre-dilution and post-dilution Internal bar code reader optional Function Used for sample and reagent programming Compatible Bar Code Systems Codabar, ITF (Interleaved Two of Five), Code 128, Code 39, UPC/EAN, Code 93 Communication Capability Supports bi-directional communication with LIS (Laboratory Information System)
Reaction System
Reaction rotor Rotating tray, containing 40 cuvettes Cuvette Reusable, optical length 5mm Reaction volume 100~360μl Operating temperature 37℃ Temperature fluctuation ± 0.1℃ ISE Module Optional Parameters Measured K⁺, Na⁺, Cl⁻ Mixing Unit Independent mixing bar Cuvette Washing Washing station with pre-warmed detergent Optical System
Light Source Halogen-tungsten lamp Wavelength 8 wavelengths, 340nm、405nm、450nm、 510nm、546nm、578nm、630nm、670nm Absorption range 4.0 Abs (10mm conversion), resolution 0.0001Abs Stray Light 5.6Abs Optical System
Calibration modes Linear (one point, two points and multi-points), Logit-Log 4P, Logit-Log 5P, spline, exponential, polynomial, parabola Control Rules X-R, L-J, Westgard multi-rule, Cumulative sum check, twin plot Operation Unit
Operation system Windows 8 Interface RS-232 Working Conditions
Power Supply 200~240V, 50/60Hz, ≤1000VA or 100~130V, 60Hz, ≤1000VA Dimension 690 mm (length) ×580 mm (depth) ×595 mm (height) Weight 79 kg Water Consumption ≤ 4 L/H DOWNLOADABLE PDF