top of page

Mindray EU-5600Pro

SKU: EU-5600Pro
  • 2K full-color clear imaging, reducing the rate of manual microscopic review for positive samples

  • High analysis volume for sediment particles to avoid missed diagnosis of positive samples

 

  • ADDITIONAL INFORMATION

    Unveiling the Unseen by Unlocking Unparalleled Clarity

     

     

    2k full-color clear imaging, reducing the rate of manual microscopic review for positive samples

    Colorful imaging technique which is close to manual microscopic satisfies what you need for releasing a report

     

    High analysis volume for sediment particles to avoid missed diagnosis of positive samples

    The system captures up to 60 clear images from the samples. Utilizing advanced algorithm, the system can precisely identify various types of formed elements from panoramic images, thereby minimizing the chances of missed positive samples.

     

    Dry chemistry analysis delivers precise results that are better aligned with the analysis of formed elements.

    The test strip for dry chemistry analysis are optimized to enable precise sampling, thereby ensuring accurate results, consistent performance, and greater ease of use.

     

    Safety and ease of use, and efficient review

    The system supports running urine samples with closed tubes, ensuring enhanced levels of biosafety. With the inclusion of Mindray data management software—LabXpert, the system shows dry chemistry, urine formed elements, and RBC phase results on a single screen, significantly improving the efficiency of report validation

     

    Coming standard with RBC phase parameters to help rapidly identify the source of hematuria
    The system can automatically provide parameters for various types of urinary RBCs, presenting histograms that clearly depict the size, shape, and hemoglobin content of these cells. By analyzing the results of RBC morphological variations (Morinfo-RBC: homogeneous/heterogeneous/mixed) and utilizing RBC morphological images, a thorough review and validation process can be conducted to identify the source of hematuria rapidly and precisely.

     

    Three features integrated in a single system to manage the unique workflow needs of your lab

    The integration of dry chemistry, formed element, and RBC phase analysis leads to a great improvement in time and space management efficiency. Even a single person can easily manage the TAT requirements during the peak hours of your lab.

    • Automated dry chemistry analysis 
    • Manual RBC phase analysis
    • Automated formed element analysis

     

  • SPECIFICATIONS

    Testing principles  
    Dry chemistry: Photoelectric colorimetry, refractometry, and Nephelometry method
    Formed elements: Machine vision (Digital imaging technology )
    Reportable parameters  
    Physical: Specific gravity, color, and turbidity
    Dry chemistry:

    11/14 items

     

    LEU, leukocyte

    URO, urobilinogen

    PRO, protein

    BIL, bilirubin

    GLU, glucose

    VitC, vitamin C

    SG, specific gravity

    KET, ketones

    NIT, nitrite

    pH, power of hydrogen

    BLD, erythrocyte

    MCA, micro albumin

    CRE, creatinine

    CA, calcium

    P/C, protein-to-creatinine ratio*

    A/C, microalbumin-to-creatinine ratio*

     

    Note: Parameters indicated with an asterisk (*) are intended for calculated parameters

    Formed elements:

    31 kinds

     

    RBCs (total)

    Normocytic, Nor-RBC

    Macrocyte, Mac-RBC

    Microcyte, Mic-RBC

    Crenocyte, Cre-RBC

    Annular RBCs, Ann-RBC

    Acanthocytes, Aca-RBC

    Humped Spherocytes, Hpd-RBC

    Jagged RBCs, Jag-RBC

    Ghost RBCs, Gho-RBC

    Fragmented RBC, Fra-RBC

    Other abnormal RBCs, Oab-RBC

    Anisocytosis Ratio, Ani-Ratio

    MorInfo-RBC

    WBC, white blood cells

    WBCC, white blood cells clump

    BACT, bacteria

    BACTc, coccus

    BACTr, rod

    YST, Yeast

    Squamous epithelial cell, SEC

    Non squamous epithelial cell, NEC

    CRYS, Crystals

    Mono-hydrate calcium oxalate crystal, Caoxm

    Di-hydrate calcium oxalate crystal, Caoxd

    Uratic crystal, URA

    Triple phosphate crystal TRP

    HYAC, hyaline cast

    UNCC, unclassified cast

    MUC, mucous strands

    Sperm, SPRM

    Throughput  
    Dry chemistry mode: ≥160 tests/ hour
    Formed element mode: ≥100 tests/ hour
    Hybrid mode: ≥100 tests/ hour

     

    Automated focusing The system automatically performs the focusing process, without the need for manual operation or the use of focus reagents
    STAT function Independent STAT positions for emergency samples at any time
    Strips loading capacity 200
    Sample Volume 2.5ml minimum required sample volume
    Sample type Native urine sample
    Barcode Built-in barcode reader
    Tube specication Length ≤110mm Diameter 15-16mm
    Communication Bi-direction LIS, automated barcode identification for testing
    Dimensions and Weight WxDxH: 600x770x530(mm) / ≤71.5Kg

     

Order products like this and more call 305-593-2137 or fill out the form below.

Contact us

bottom of page