Siemens Atellica CH930
Engineered for performance, the Atellica CH930 delivers high-throughput clinical chemistry testing with precision, speed, and seamless integration — empowering laboratories to scale without compromise.
ADDITIONAL INFORMATION
Atellica Solution
Flexible, scalable, automation-ready immunoassay and clinical chemistry analyzers engineered to deliver control and simplicity so you can drive better outcomes
Experience the power of the Atellica® Solution, featuring patented bidirectional magnetic sample transport technology, the flexibility to create over 300 customizable configurations, and a broad assay menu with proven detection technologies.
The Atellica® CH 930 Analyzer uses proven micro-volume technology for photometric testing and highly reliable integrated multisensor technology (IMT) for electrolyte testing. The Atellica CH 930 Analyzer uses the same reagents and consumables in every configuration for streamlined inventory management and consistent patient results, no matter where the samples are tested.
Up to six Atellica CH 930 Analyzers can be connected in the Atellica Solution to accommodate chemistry testing volume.
At Siemens Healthineers, our purpose is to enable healthcare providers to increase value by empowering them on their journey toward expanding precision medicine, transforming care delivery, and improving patient experience, all made possible by digitalizing healthcare.
An estimated 5 million patients globally benefit every day from our innovative technologies and services in the areas of diagnostic and therapeutic imaging, laboratory diagnostics, and molecular medicine, as well as digital health and enterprise services.
We are a leading medical technology company with over 120 years of experience and 18,000 patents globally. Through the dedication of more than 50,000 colleagues in 75 countries, we will continue to innovate and shape the future of healthcare.
A-LYTE, Atellica, and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc., or its affiliates. All other trademarks and brands are the property of their respective owners.
Product availability may vary from country to country and is subject to varying regulatory requirements. Please contact your local representative for availability.
TECHNICAL SPECIFICATIONS
PRODUCT SPECIFICATIONS
Description Chemistry analyzer with electrolyte (IMT) and photometric testing capabilities Test Throughput Up to 1800 tests/hour: 1200 tests/hour photometric, 600 tests/hour IMT Walkaway Time Up to 5 hours SAMPLE HANDLING
Validated Sample Types Serum, plasma, CSF, urine, whole blood (assay-specific) Sample Integrity Control Liquid-level sensing, clot detection, bubble detection, short-sample detection; hemolysis, icterus, and lipemia checks Auto-repeat Automatic repeat testing from the retained prediluted sample or original sample Sample Dilution For most photometric tests, samples diluted 1:5 (50 μL sample + 200 μL CH diluent generates up to 15 test results) Auto-reflex Testing Will perform additional tests based on results of first test or test combination Sample Carryover Prevention Extensive washing protocols help minimize carryover Predilution Tray 115 dilution cuvettes: five segments of 23 cuvettes Sample Volume per Test Photometric: 4.0 μL to 50.0 μL (varies by assay) IMT: 25 μL produces results for sodium (Na+), potassium (K+), and chloride (CL- REACTION AREA
Reaction Cuvette 221 reusable plastic cuvettes: 13 segments with 17 cuvettes each for reaction Reaction Temperature 37°C ±0.3°C Reaction Detection Photometer: 11 fixed wavelengths (340, 410, 451, 478, 505, 545, 571, 596, 658, 694, 805 nm) Light Source 12 V, 50 W halogen lamp supplemented by LED at 340 nm Assay Result Calculations Endpoint (EPA), rate reaction (RRA), 2-point rate (2PA), sample blank correction Assay Times 3–10 minutes, assay-dependent Assay Technology Integrated Multisensor Technology, photometric, turbidimetric REAGENT HANDLING
Reagent Compartments Two trays (70 positions each), refrigerated Assays Onboard Each reagent compartment holds a total of 70 packs for photometric, Reagent Probe Cleaner (RPC), and Water Bath Additive (WBA). Both compartments combined hold a total of 140 packs. Reagent Packs 50 mL dual-well reagent containers (2 x 25 mL each); 95–2100 tests per pack Reagent Integrity Control Reagent pack bar-code identification; automatic tracking and notification of inventory, calibration and control validity, onboard stability, low and expired reagents, detection of reagent bubbles Onboard Stability Up to 60 days, assay-dependent Reagent Inventory Management Automatic tracking and notification of remaining tests, onboard stability and expiration, calibration, and storage conditions for each pack and well Dispensing System Two probes with liquid-level sensing Bar-code-labeled Packs Yes Average Reagent Volume 10–100 μL per test, assay-dependent Open Channels Available; configurable to assay specifications INTEGRATED MULTISENSOR TECHNOLOGY (IMT) FOR Na+, K+, CI-
Assay Time 18 seconds Sample Volume 25 μL produces three results Sample Dilution Automatic 1:10 Calibration Automatic calibration Priming Automatic priming cycle A-LYTE™ Integrated Multisensor Technology Cartridge Use Life Up to 5000 samples or 14 days CALIBRATION/QC
Auto-calibration Automatic assay-specific lot and pack calibration (when connected to Atellica® Sample Handler) Calibration Review Graphical display of calibration curves from a minimum of 20 different reagent lots and 20 reagent packs for each assay Auto-QC Automatic, user-defined, assay-specific quality control (when connected to Atellica Sample Handler) Quality Control Review Advanced QC package with graphical display of QC in real time, including patient moving averages, Levey-Jennings plots, Westgard rules, RiliBÄK rules; up to 125,000 control results can be stored; archivable to removable media QC/Calibration Material QC and calibration material is auto-loaded, tracked, and stored in a 60-position covered and refrigerated compartment and automatically deployed to analyzers when QC or calibration is scheduled (when connected to Atellica Sample Handler) MAINTENANCE
Daily Automated: 22–50 minutes;*† hands-on: <5 minutes Weekly Automated: 65 minutes; hands-on: 5 minutes Weekly IMT Automated: 10 minutes Monthly Hands-on: 15 minutes As Needed Refer to Online Help for additional periodic maintenance. Maintenance Logs Automated onboard scheduling, notification, and reporting GENERAL SPECIFICATIONS
Power Requirements Requires a 4.4 kVA (U.S.)/3.7 kVA (EU) power source; single-phase, 2-pole, 3-wire configuration; with Class III grounding. Will support incoming AC voltage from a nominal line voltage range of 200 to 240 VAC, 50/60 Hz. Main supply voltage fluctuations are not to exceed ±10 percent of the nominal voltage. Power Consumption 1.9 kilowatts/hour (maximum) Water Input Requirements Incoming pressure of 5–30 psi at a temperature of 10–30°C Water Quality Requirements Special reagent grade water‡ Maximum Water Consumption 33 liters (8.7 gallons) per hour Drain Requirements Minimum of 40 liters (10.6 gallons) per hour per analyzer Dimensions 136.4 (h) x 149.1 (w) x 115.6 (d) cm; 53.7 (h) x 58.7 (w) x 45.5 (d) inches Weight 470 kg (1036 lb) Compliance Complies with international environmental, health, and safety standards, including CE and RoHS Noise Emission Average sound pressure level: 50 dBA Processing Heat Output 5210 BTU/hour Ambient Temperature 18–30°C (64–86°F) Ambient Humidity 20–80% noncondensing Altitude 0–2000 m (6561 feet) Floor Load-bearing Requirement 274 kg/m2 Overvoltage Classification Category II Pollution Classification Degree 2 Removable Media USB DOWNLOADABLE PDF